Verilink 8000 Series IADs 8224S

  1. Start the console session.

    Plug in serial cable to console port of device from PC COM1 port
    Open PuTTY and select "Serial" connection type, change baud rate (Speed) to 19200 and leave other settings as default.
    Plug power into device and if a power button exists, turn it on.
  2. Log in with Supervisor credentials.

    Allow the boot process to complete and press a key when prompted to continue:
    ************************************************** * Boot Manager Ver 2.8.0 ************************************************** ===Testing 16 MBytes of DRAM ................................................................PASSED! Press B to enter Boot Utility... Now loading system software. Please wait... ************************************************************ *** RTOS start sequence *** ***Please wait. Initialization may take several minutes.*** ************************************************************ Enter "i" to Inhibit Application Launching only Enter "I" to additionally Inhibit Initialization (minimal startup) Last Reset: Reset Events: Ext hard Ext soft Initializing hardware... ************************************************************* * Verilink Corp. * * <=> 8224s 8000 Series IAD v3.8.1-R1 <=> * * Dec 9 2005 15:10:18 * * (C) 1998-2005 by Verilink Corp * ************************************************************* Version Name:LO8x16_8x24-3.8.1-R1 … [01 00:00:25.715] Predefined parameters was loaded from NVRAM [01 00:00:25.715] Variant database loaded. [01 00:00:25.720] Interface is Out Of Service DERIVED TIMING enabled on T1/E1 interface Press any key to continue...
    Type the case-sensitive Supervisor username for Login ID and type supervisor for password:
    Enter Login ID > Supervisor Enter Password > supervisor Logged in with Security Level = Supervisor
  3. Erase configuration.

    In the Main Menu type 9 for "System Utilities":
    ***************************************** * Main Menu * ***************************************** 1. Reports Menu 2. Configure IP Router 3. Configure Bridge 5. Configure WAN 6. Configure LAN 7. Configure SNMP 8. Configure Login 9. System Utilities I. Interworking Connections D. Configure DHCP Server M. Configure Multicast N. Configure NAT T. Telephony Clock Recovery Z. Diagnostics Menu C. Command Line Interface Q. PPP Options Menu P. VoicePath Configure R. Reset System E. AAL2/LES CCS-ELCP ESC to log off menu system ->9
    In the Utilities Menu type d to "Set System Defaults" and confirm with y:
    *************************************************** * Utilities Menu * *************************************************** P. Ping Utility T. Trace Route Z. Configure Console Baud Rate V. Configure Console Timeout R. Hard Reset or Reload ACOS from FLASH D. Set System Defaults W. Save System Settings as Defaults E. Display Event Log L. Clear Event Log A. Clear "Last Reset Reason" M. Time Menu N. Display Configuration File F. File System Menu G. Debug Menu X. File Transfer Menu ESC to return to previous menu ->d WARNING: System will be reset after default configuration is saved Press Y to Set Factory Defaults now->y Saving Default Configuration... Now Resetting...
  4. Copy all the output from the session into your records.

    Right-click PuTTY's titlebar, from that dropdown menu click on "Copy All to Clipboard"
    Open the file of record certifying the deconfiguration of this device and use CTRL V to paste all the output from PuTTY into that file. Formatting the text with a fixed-width font helps it look more readable.
  5. End the session.

    Close PuTTy.