Start the console session.
Plug in serial cable to console port of device from PC COM1 port
Open PuTTY and select "Serial" connection type, leave baud rate (Speed) and other settings as default.
Plug power into device and if a power button exists, turn it on.
Access single user mode.
Press ESC when prompted and before the countdown ends:
System RAM test using Default POST RAM Test succeeded.
set_bootstatus: BS_LOAD_OS, platform_idx = 2
Hit ESC to stop autoboot: 0
Type 3 for the command shell:
1) Start system.
2) Recover password.
3) Enter command shell.
Option? 3
Type the setenv OSLoadOptions single command:
Boot PROM password has not been set.
=> setenv OSLoadOptions single
Type the printenv command noting the value of "OSRootPartition" for the next step:
=> printenv
AutoLoad=yes
AutoLoadTimeout=4
InitTest=MEM()
LoadIdentifiers=Fabric Operating System;Fabric Operating System
OSLoadOptions=single
OSLoader=ATA()0x15945f;ATA()0x3a25e0
OSRootPartition=hda1;hda2
SkipWatchdog=yes
baudrate=9600
bootcmd=setenv bootargs mem=${mem} ${OSLoadOptions};ataboot;bootm 0x400000
bootdelay=20
bootfile=net_install.img
eth1addr=00:27:F8:20:F4:A2
eth2addr=00:27:F8:20:F4:A3
eth3addr=00:27:F8:20:F4:A4
ethact=ENET0
ethaddr=00:27:F8:20:F4:A1
gatewayip=192.168.17.65
initrd_high=0x20000000
ipaddr=192.168.17.93
mem=2093056k
netmask=255.255.255.224
serverip=10.210.1.80
stderr=serial
stdin=serial
stdout=serial
Environment size: 625/4080 bytes
Type the boot command:
=> boot
Map file at LBA sector 0x15945f
## Booting image at 00400000 ...
Image Name: Linux-2.6.14.2
Image Type: PowerPC Linux Multi-File Image (gzip compressed)
Data Size: 2672703 Bytes = 2.5 MB
Load Address: 00000000
Entry Point: 00000000
Contents:
Image 0: 1594026 Bytes = 1.5 MB
Image 1: 1078663 Bytes = 1 MB
Uncompressing Multi-File Image ... ## Current stack ends at 0x7FB65A40 => set upper limit to 0x00800000
## initrd at 0x005852F8 ... 0x0068C87E (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Memory CAM mapping: CAMS=2000Mb residual: 44Mb
tlbcam_index=11
Linux version 2.6.14.2 (swrel@hq1-ub-ecbld-392) (gcc version 3.4.6) #1 Thu Jan 9 07:31:14 PST 2014
Further output will bring you to the sh-2.04# prompt.
Reset passwords.
Type the mount -o remount,rw,noatime / command then the mount /dev/hda2 /mnt command to enable changing settings:
sh-2.04# mount -o remount,rw,noatime /
EXT3 FS on hda1, internal journal
sh-2.04# mount /dev/hda2 /mnt
kjournald starting. Commit interval 5 seconds
EXT3 FS on hda2, internal journal
EXT3-fs: recovery complete.
EXT3-fs: mounted filesystem with ordered data mode.
Type the /sbin/passwddefault command:
sh-2.04# /sbin/passwddefault
All account passwords have been successfully set to factory default.
Return from single user mode next boot-up with the bootenv OSLoadOptions "quiet/quiet" command:
sh-2.04# bootenv OSLoadOptions "quiet/quiet"
Type the reboot -f command:
sh-2.04# reboot -f
Restarting system.
.
The system is coming up, please wait...
Further output will bring you to the console login: prompt.
Log in with default credentials and erase configuration.
Type root for the login and fibranne for the password:
Fabric OS (SAN_DCX8510_20_IDC)
SAN_DCX8510_20_IDC console login: root
Password: fibranne
Disclaimer for Root and Factory Accounts Usage!
…
Proceeding with the usage of this switch as the Root or Factory user
explicitly indicates your agreement to the terms of this disclaimer.
Check the version number with the version command and find any licenses with the licenseshow command:
SAN_DCX8510_20_IDC:root> version
Kernel: 2.6.14.2
Fabric OS: v7.1.1c
Made on: Thu Jan 16 19:57:49 2014
Flash: Tue Feb 10 11:44:20 2015
BootProm: 1.0.15
SAN_DCX8510_20_IDC:root> licenseshow
3Q44ZK3a7mQmEYCX3TWD3NSFQgKKtAGfBS4SA:
Extended Fabric license
Fabric Watch license
Performance Monitor license
Trunking license
Adaptive Networking license
Server Application Optimization license
Type the switchdisable command putting it in a mode that allows resetting the configuration:
SAN_DCX8510_20_IDC:root> switchdisable
Type the configdefault command followed by the switchenable command to return to the previous mode:
SAN_DCX8510_20_IDC:root> configdefault
Executing configdefault...Please wait
Already in Native Mode continuing with configDefault
2022/07/26-08:57:39, [FCR-1069], 7121, SLOT 4 | FID 128, INFO, SAN_DCX8510_20_IDC, The FC Routing service is enabled.
2022/07/26-08:57:39, [FCR-1068], 7122, SLOT 4 | FID 128, INFO, SAN_DCX8510_20_IDC, The FC Routing service is disabled.
2022/07/26-08:57:39, [FCR-1070], 7123, SLOT 4 | FID 128, INFO, SAN_DCX8510_20_IDC, The FC Routing configuration is set to default.
Committing configuration ... done.
Both CPs have to be rebooted to allow the changes to take effect.
2022/07/26-08:57:39, [CONF-1031], 7124, SLOT 4 | FID 128, INFO, SAN_DCX8510_20_IDC, configDefault completed successfully for switch.
SAN_DCX8510_20_IDC:root> switchenable
2022/07/26-08:57:46, [SWCH-1001], 7125, SLOT 4 | FID 128, ERROR, SAN_DCX8510_20_IDC, Switch is not in ready state - Switch enable failed, switch status= 0x4, c_flags = 0x10400.
Type the reboot command:
SAN_DCX8510_20_IDC:root> reboot
Warning: This command is being run on a control processor (CP)
based system and will cause the active CP to reboot.
This will cause disruption to all traffic in this chassis.
Are you sure you want to reboot the active CP [y/n]?y
2022/07/26-08:57:53, [RAS-1007], 7126, SLOT 4 | CHASSIS, INFO, DCX8510_20_IDC, System is about to reboot.
Broadcast message from root (ttyS0) Tue Jul 26 08:57:57 2022...
The system is going down for reboot NOW !!
INIT: Switching to runlevel: 6
INIT: Sending processes the TERM signal
SAN_DCX8510_20_IDC:root> HAM: Ask go to reboot, SCN_GO_REBOOT
XPRT Link Down
fcsw:0-auth: Image-incomplete event
chassis:0-bm: Image-incomplete event
bonding: bond0: released all slaves
eth1: Link is down
eth2: Link is down
##RSCMON exiting due to signal: 19, pending signals: 0x0, 0x0
##exiting due to signal: 19, pending signals: 0x0, 0x0
Stopping diagnostics
Stopping diagnostics
nfsd: last server has exited
nfsd: unexporting all filesystems
Unmounting all fStopping diagnostics
ilesystems.
Stopping diagnostics
Stopping diagnostics
Stopping diagnostics
Please stand by while rebooting the system...
Restarting system.
.
The system is coming up, please wait...
Copy all the output from the session into your records.
Right-click PuTTY's titlebar, from that dropdown menu click on "Copy All to Clipboard"
Open the file of record certifying the deconfiguration of this device and use CTRL V to paste all the output from PuTTY into that file. Formatting the text with a fixed-width font helps it look more readable.
End the session.
Close PuTTy.